What Is U4038 Abend In Cobol?
A U4038 abend is a user-abend which comes from Language Environment, the “run-time” for Mainframe programs (it supports multiple Mainframe languages).
What is Abended s000 U4038?
A U4038 abend is typically a Language Environment abend. The 4038 means that another error occurred in the program and LE is shutting down the program.
What is user Abend code 4038?
In this particular case, the abend 4038 is due to the COBOL application dynamically calling a module that is not available; this could be due to specifying an incorrect module name on the CALL or the module might not exist.
What is abends in mainframe?
An abend occurs when the host system cannot resolve an error condition generated by the program. The term’s origin is attributed to the IBM 360 operating system that ran on IBM mainframe computers in the 1960s and 1970s.
What are the abends in Cobol?
The ABEND macro is used to initiate error processing for a task. ABEND can request a full or tailored dump of virtual storage areas and control blocks pertaining to the tasks being abnormally terminated, and can specify that the entire job step is to be abnormally terminated.
What is U4038?
A U4038 abend is a user-abend which comes from Language Environment, the “run-time” for Mainframe programs (it supports multiple Mainframe languages).
What is the reason for the Abend message a file open error?
Possible causes:
An attempt to open an open file. There was a conflict between the program, the JCL DCB, and the data set DCB information. An incorrect block or record length was specified. An attempt was made to write to an input data set.
What is AFCY abend?
You receive an abend AFCY for a transaction suspended waiting on resource FCSRSUSP. This is a wait for shared resource string indicating that the file is using a local shared resource (LSR) pool.
What is S722 abend?
An abend S722 (output limit exceeded) occurred when the TEMS was attempting to stop programs that it had started.
What is S122 abend?
Code. Description. S122. The operator canceled the job and requested a dump.
What is S322 abend in JCL?
On a mainframe, a job abends with an S322 abend code when the TIME value has been exceeded on a per job or per step basis.
What is S522 abend in JCL?
The S522 abend is not a typical job time exceeded error, it’s a job wait time exceeded. That is to say, the time allocated to wait in an SVC wait state was exceeded.
What is U0016 abend in JCL?
Explanation: This abend occurs because of a fatal processing error in module DX10ROLL as Extractor data set and volume records are concatenated together. Message DSO501 often appears with abend U0016. The most common cause of the abend is improper concatenation of Extractor data.
What is abend U4087 in COBOL?
The U4087 is an LE abend that indicates a recursive error was detected, and reason code=3 indicates that a language-specific condition handler was processing a condition (signal error) when a subsequent condition (endpage) was raised.
How do you resolve se37 abend in JCL?
Give space parameters so that you can your dataset can fit in. You can just go to your JCL and change DD name to a new one.
Steps to Fix Space Abend:
- Evaluate the “peak” volume of the output data set (CYLs or TRKs).
- Use 50% of the “peak” volume as primary space and 10% of the peak volume as secondary space.
What is CEE3ABD?
CEE3ABD ( abcode , clean-up ) abcode (input) A fullword integer, no greater than 4095, specifying the abend code that is issued. Under CICS®, this fullword integer is converted to EBCDIC.
How do you resolve a SOC1 Abend?
A SOC1 abend is an Operation Exception and caused by an invalid instruction. Remember that Cobol is compiled to produce the assembly instructions in object module format. That goes into the link edit step to produce the load module. The most common reason for a SOC1 is an unresolved external reference from link edit.
What are the two types of error messages?
- Warning. A warning indicates that there is a possible problem.
- Lexical error. A lexical error occurs when part of an expression is missing or is invalid.
- Syntax error. A syntax error occurs when an expression contains a syntax mistake.
- Evaluation error.
- Invalid number.
- System error.
- Out of memory error.
- See Also.
What is u0999 abend?
ABENDU0999 or USER COMPLETION CODE=0999 issued by IQCSELCT
If USER COMPLETION CODE=0999 occurs, this is most likely the result of insufficient memory. To correct the error, run the job again using a larger region size on your IQCSELCT JOB or STEP card.
What is U4093 abend?
An abend U4093 indicates that a sockets extended call that is not valid has been detected. It is issued by EZASOKET following a call to EZASOKFN if EZASOKFN has detected an error in the socket call parameter list.
What is S722 abend in COBOL?
The S722 ABEND is specific to the SYSOUT limit. Receiving the ABEND722 indicates the SYSOUT limit was reached.
Contents